PV1-F Twin core Solar Cable

These special type cables are used for solar system solar panel connection. The jacket and insulation of the cable are made by XLPO which can keep the cable a good performance under the sunlight and strict weather. Normal Voltage is AC1000/1000V DC1500V/1500V. The working time of this cable can be 25 years.

Standard and Approvals

TÜV 2 PfG 1169/08.2007
Weather und UV resistant acc.to HD 605/A1
Halogen-free acc. to EN 50267-2-1 IEC670754-1
Resistant to acid and bases acc. to EN60811-2-1
Flame-resistant acc. to VDE 0482-332-1-2 DIN EN 60332-1-2
O-zone resistance acc. to: EN50396
Smoke density: IEC61034, EN50268-2

Cable Structure:

Conductor: Tinned copper
Insulation: Cross-linked polyolefin
Jacket: Cross-linked polyolefin

Technical data:

Resistant to short-circuits up to 200°C
Hydrolysis and ammoniac-resistant
Voltage Rating Uo/U
AC: 1000/1000V
DC: 1500/1500V
Maximum Voltage (Umax): 1800V
Test Voltage: 6.5kV AC
Temperature Rating Fixed: -40° C to +90° C
Minimum Bending Radius: 4 x overall diameter
Maximum Conductor Temperature: +120° C (for 20000h)
The Expected Service Life: 25 years
Cross section (mm2)Conductor construction (No./mm)Insulation Ave.Thic.(mm)Sheath Ave.Thic. (mm)Cable outside diameterminimum outer diameter(mm)Max Cond Resistance (Q/km,20°C)Current carring Capacity AT 60° C(A)
2*1.530/0.250.700.805.00*10.3013.730
2*2.550/0.250.700.805.20*10.808.2141
2*4.056/0.2850.700.805.50*11.205.0955
2*6.084/0.2850.800.906.20*12.603.3970
2*10142/0.300.901.17.50*15.201.9598
2*16228/0.301.11.19.60*19.701.24132

Request A Free Quote

Or contact us to see our certificates

We'd like to work with you

Send us a message if you have any questions or request a quote. Our experts will give you a reply within 24 hours and help you select the right valve you want.

Get in Touch