FHLR2GCB2G Cable

These shield Silicon electric vehicle high voltage cables are used in areas such as connecting batteries internally, batteries to engines and other components, and battery storage devices as carriers for power transmission.

Standard and Approvals

LV 216-2 table A2, Daimler AG C51 / 11.14, VW N 107 776,
BMW GS 95007-6-2

Cable Structure:

– Conductor:Class 6 fine flexible stranded Copper
– Insulation:SiR (Silicon rubber)
– Screening Armor:Tinned copper (85% minimum coverage)
– Foiled Armor:ALU-PET foil (20% minimum overlap)
– Outer sheath:SiR (Silicon rubber)
– Sheath Colour:Orange

Technical data:

Voltage Rating : 0.6/1kV
Test Voltage : spark test 8kV 5 minutes: 5kV
Temperature Rating :
Operating temperature: -40ºC to +180ºC 3000 (hours)
Short term ageing: +205 ° C 240 (hours)
Minimum Bending Radius :
Static installation: 2 x overall diameter
Dynamic Installation: 4 x overall diameter
 

Datasheet

NOMINAL CROSS
SECTIONAL AREA
mm2
CONDUCTOR
DIAMETER
mm
INSULATION
THICKNESS
mm
NOMINAL OVERALL
DIAMETER
mm
NOMINAL
WEIGHT
g/m
2570.6412.2345
358.50.6414.4485
50100.7115.8630
7012.50.818.2880
951480.920.91150

Request A Free Quote

Or contact us to see our certificates