Twin core PV1-F Cable

These special type cables are used for solar system solar panel connection. The jacket and insulation of the cable are made by XLPO which can keep the cable a good performance under the sunlight and strict weather. Normal Voltage is AC1000/1000V DC1500V/1500V. The working time of this cable can be 25 years.

Standard and Approvals

TÜV 2 PfG 1169/08.2007
Weather und UV resistant acc.to HD 605/A1
Halogen-free acc. to EN 50267-2-1 IEC670754-1
Resistant to acid and bases acc. to EN60811-2-1
Flame-resistant acc. to VDE 0482-332-1-2 DIN EN 60332-1-2
O-zone resistance acc. to: EN50396
Smoke density: IEC61034, EN50268-2

Cable Structure:

Conductor: Tinned copper
Insulation: Cross-linked polyolefin
Jacket: Cross-linked polyolefin

Technical data:

Resistant to short-circuits up to 200°C
Hydrolysis and ammoniac-resistant
Voltage Rating Uo/U
AC: 1000/1000V
DC: 1500/1500V
Maximum Voltage (Umax): 1800V
Test Voltage: 6.5kV AC
Temperature Rating Fixed: -40° C to +90° C
Minimum Bending Radius: 4 x overall diameter
Maximum Conductor Temperature: +120° C (for 20000h)
The Expected Service Life: 25 years
Cross section (mm2)Conductor construction (No./mm)Insulation Ave.Thic.(mm)Sheath Ave.Thic. (mm)Cable outside diameterminimum outer diameter(mm)Max Cond Resistance (Q/km,20°C)Current carring Capacity AT 60° C(A)
2*1.530/0.250.700.805.00*10.3013.730
2*2.550/0.250.700.805.20*10.808.2141
2*4.056/0.2850.700.805.50*11.205.0955
2*6.084/0.2850.800.906.20*12.603.3970
2*10142/0.300.901.17.50*15.201.9598
2*16228/0.301.11.19.60*19.701.24132